Search results for "Brunescent cataract"

showing 2 items of 2 documents

Late postoperative opacification of MemoryLens hydrophilic acrylic intraocular lenses Case series and review

2003

Abstract Purpose: To report clinical and spectrographic analyses of 2 explanted hydrophilic acrylic intraocular lenses (IOLs). Setting: John A. Moran Eye Center, Salt Lake City, Utah, USA, and Johannes Gutenberg-University, Department of Ophthalmology, Mainz, Germany. Methods: We report 6 cases of opacification of MemoryLens ® IOLs (Ciba Vision) that occurred approximately 2 years after implantation. The anterior and posterior surfaces of the IOLs had a white, frosted appearance, and the IOLs' interior looked brown, similar to the appearance of a brunescent cataract. Two of the IOLs were explanted because of a significant decrease in visual acuity. The IOLs were sent for further clinicopath…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVision DisordersVisual AcuityIntraocular lensSalt lakeLens Implantation IntraocularDevice removalOphthalmologymedicineHumansDevice RemovalAgedAged 80 and overLenses IntraocularPhacoemulsificationElectron probe microanalysisbusiness.industryCalcinosisPhacoemulsificationeye diseasesSensory SystemsProsthesis FailureOphthalmologyIntraocular lensesCalciumFemaleSurgerysense organsBrunescent cataractmedicine.symptombusinessElectron Probe MicroanalysisJournal of Cataract & Refractive Surgery
researchProduct

Evaluation of the improvement of sensibility with the new IOL Master software version 5.4.3

2009

Purpose To evaluate the improvement of sensibility of the new IOL-Master version 5.4.3 compared with the version 4.08. Methods 214 eyes of 115 patients were examined in a cataract preoperative evaluation making use of both IOL-Master software versions 5.4.3 and 4.08. The type and severity of the lens opacification was assessed by slitlamp biomicroscopy. Results In 182 of the eyes examined both versions were capable to determine the AL; in 29 the version 4.01 could not determine AL whereas the version 5.4.3 was able to measure it; these cases showed posterior capsular cataract (16), dense nuclear cataract (11), posterior synechiae (1) and asteroid hyalosis (1). Finally, the AL of 3 eyes coul…

Posterior capsular cataractmedicine.medical_specialtyNuclear cataractAsteroid hyalosisbusiness.industryGeneral Medicinemedicine.diseaseOphthalmologyOphthalmologyVitreous hemorrhagemedicineSensibilityPosterior synechiaeBrunescent cataractbusinessActa Ophthalmologica
researchProduct